Need 3-Phase Power?
Superior Phase Converters are the best in rotary phase converters!




WHAT ARE SOME OF THE APPLICATIONS SUPERIOR PHASE CONVERTERS RUN?

Machine shops, Small factories, Elevators, Compressors, Sawmills, Hoists, Pumps, Farms, Fire Sirens, CNC machines, Woodworking shops, Computers, Irrigation, Sewage plants, and Welders

SHOULD SUPERIOR PHASE CONVERTERS BE STARTED FIRST?

Yes! When Superior Phase Converters are running, you may start and stop motors without any limitations or sequences.

HOW IS THE CORRECT SUPERIOR PHASE CONVERTER DETERMINED?

Each model is rated in HP with given parameters. As a rule we size by the largest motor and total HP of smaller motors to be operated. Once this information is obtained a sizing selection may be made. Other considerations are type of application, as various equipment operates differently. In short, it is best to consult one of Superior Phase Converts’ factory engineers as to your individual needs.

WHAT IS THE LIFE SPAN OF SUPERIOR PHASE CONVERTERS?

Typically Superior Phase Converters will outlast the equipment that it operates. The converter is designed to run continuously at low amperage, so it stays cool. You can expect many years of trouble free service from these units.

IS IT EXPENSIVE TO OPERATE SUPERIOR PHASE CONVERTERS?

No! Energy savings is the heart of the Superior Phase design. Customers often say they leave Roto-Master running during lunch hours and other periods of work stoppage, without a noticeable increase in their electric bill.

CAN SUPERIOR PHASE CONVERTERS IDLE AT NO LOAD WITHOUT OVERHEATING?

Yes! Balancing the current on each winding allows this. Since some models on the market are unbalanced, you will need to constantly start and stop the unit to prevent overheating, resulting in additional power consumption and inconvenience.

DOES SUPERIOR PHASE CONVERTERS REQUIRE EXCESSIVE CONSUMPTION OF POWER TO START?

No! Balanced converters start instantly as power is generated on each phase, resulting in low inrush amperage. Some converters on the market use only one phase of the converter winding, resulting in longer starting time and high current draw on the utility lines. This often results in power drops and flickering for the customers and the utility companies. The Roto-Master starts in approximately 2-3 seconds.

WHAT SIZE SHOULD MY ELECTRIC SERVICE BE?

This will depend upon the total HP that runs at one time. Add all three phase current (amperage) and multiply by 2.15 to convert to single phase, this allows for service size, wiring, etc. Superior Phase Converters’ engineers are available to help you determine your service needs.

ARE SUPERIOR PHASE CONVERTERS DIFFICULT TO INSTALL?

No! It is among the easiest to install because there is a terminal block connector inside the pre-wired control panel for added convenience.

For more information on this story, please contact:

Superior Phase Converters, LLC
PO Box 14045
3021 Standridge Rd.
Anderson, SC 29624
Phone: 864-261-7172 or 800-603-7636
Web: www.superiorphase.com
Email: sales@superiorphase.com


[Get Copyright Permissions] Click here for copyright permissions!
Copyright 2010 Cygnus Business Media